System Preparation and Configuration
DS2000 Hardware Manual Section 1: Installing the Cabinet 1-5
1
DS2000 Conguration Guidelines
The total number of components you can install and connect depends on power supply capacity and the Sys-
tem Load Factor. Review the DS2000 Conguration Guidelines table below and DS2000 Load Factor Cal-
culations on page 1-6 when conguring your system.
DS2000 Conguration Guidelines
4 Slot Cabinets
Do not install more than 2 16DSTU PCBs under any circumstances.
The rst 16DDSTU PCB you install must be in the rst slot (CN1).
Maximum conguration is
112 ports.
The total of all extensions and trunks cannot exceed
112.
Always use the System Load Factor table to check your system conguration.
8 Slot Cabinets
Do not install more than 2 16DSTU PCBs for each power supply. (Install your power supplies in the
following order: slot CN101
, slot CN103, slot CN102.)
The rst 16DSTU PCB you install must be in the rst slot (CN1).
The total of all extensions and trunks installed cannot exceed
112.
Maximum conguration is
112 ports.
Always use the System Load Factor table to check your system conguration.