Combined System Load Factor
6
Upgrading
Upgrading DS2000 to DSX-80/160
DS2000 and DSX-80/160 Combined System Load Factor Worksheet
Description Qty
Load Type
5 VDC 40 VDC
Load
Total Load Total
DSX-80/160 CPU Card 1 12 12 0 0
DSX-80/160 16ESIU Card 8 20
DS2000 16DSTU PCB 3 20
DSX-80/160 8SLIU Card 5 8
DSX-80/160 16SLIU Card 10 16
DS2000 4ASTU PCB 3 5
DS2000 8ASTU PCB 5 8
DSX-80/160 8COIU Card 3 0
DSX-80/160 16COIU Card 6 0
DS2000 4ATRU PCB 4 0
DS2000 8ATRU PCB 8 0
DSX-80/160 T1/PRI Card 8 0
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
Item 2: Power Supply Capacity
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
5 VDC = 40
5 VDC = 80
5 VDC = 120
40 VDC = 48
40 VDC = 80
40 VDC = 120
Notes:
DSX-80 can only have 1 power supply.
DSX-160 can have up to 3 power supplies. You
cannot
have more than two 16ESIU or 16DSTU Cards per power
supply, regardless of System Load Factor calculations.
Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down
and/or cause erratic system operation.
The total of all station, line, and DSS Console ports cannot exceed 160.