Combined System Load Factor
6
◆
Upgrading
Upgrading DS2000 to DSX-80/160
DS2000 and DSX-80/160 Combined System Load Factor Worksheet
Description Qty
Load Type
5 VDC 40 VDC
Load
Total Load Total
DSX-80/160 CPU Card 1 12 12 0 0
DSX-80/160 16ESIU Card 8 20
DS2000 16DSTU PCB 3 20
DSX-80/160 8SLIU Card 5 8
DSX-80/160 16SLIU Card 10 16
DS2000 4ASTU PCB 3 5
DS2000 8ASTU PCB 5 8
DSX-80/160 8COIU Card 3 0
DSX-80/160 16COIU Card 6 0
DS2000 4ATRU PCB 4 0
DS2000 8ATRU PCB 8 0
DSX-80/160 T1/PRI Card 8 0
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
Item 2: Power Supply Capacity
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
5 VDC = 40
5 VDC = 80
5 VDC = 120
40 VDC = 48
40 VDC = 80
40 VDC = 120
Notes:
• DSX-80 can only have 1 power supply.
• DSX-160 can have up to 3 power supplies. You
cannot
have more than two 16ESIU or 16DSTU Cards per power
supply, regardless of System Load Factor calculations.
• Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down
and/or cause erratic system operation.
• The total of all station, line, and DSS Console ports cannot exceed 160.